AAC, AAAC, ACSR form part of the family of Overhead Conductors, Transmission Conductors and Power Distribution Conductors. These cables are formally known as All Aluminium Conductor (AAC), All Aluminium Alloy Conductor (AAAC) and Aluminium Conductor Steel Reinforced (ACSR). These overhead aluminium conductors are used as power transmission and distribution lines.Quick Quote

We manufactures and supply AAAC with different variants of electrical grade alloy type 6101, 6201, 6061, 8006, 8030, 8176. one or more strands of hard drawn 1350 aluminium alloy.All aluminium conductors are made up of one or more strands of aluminium wire depending on the specific application.

aluminum-overhead

The specs of Overhead Line Aluminium Conductors

Specification
Alloy 1350, 6101, 6201, 6061, 8006, 8030, 8176
Type AAC, AAAC, ACSR, ACAR, PHDC
Diameter range (mm) 0.2-6.0 (Customizable diameter)
Standard ASTM B231, TS IEC 1089, DIN 48201, BS 215, UNE 21.018
Surface Quality Smooth surface, no cracks, no burrs, no inclusions
Surface treatment Coated with industrial white oil.

Popular Aluminum Overhead Line Products

AAC–ASTM-B All Aluminium Conductor

AAC (All Aluminum Conductor)** is made of high-purity aluminum (at least 99.7%), which has the advantages of light weight, good electrical conductivity, and strong corrosion resistance, but has low strength and is suitable for short-distance transmission lines and cities distribution network.

aac-conductor

AAAC-ASTM-B All Aluminium Alloy Conductor

AAAC (Aluminum Alloy Conductor)** is made of aluminum alloy and has higher strength than pure aluminum (AAC). It has a good balance of strength, weight, conductivity and corrosion resistance, and is suitable for medium-distance transmission lines and rural power grid construction.

ACSR-ASTM-B Aluminium Conductor Steel Reinforced

ACSR (Steel Core Aluminum Alloy Stranded Wire)** is composed of steel core and aluminum alloy stranded wire. It has the highest strength and is suitable for special environments such as long-distance transmission lines, high-voltage transmission lines and crossing rivers.

ACAR-ASTM-B Aluminum Conductor, Alloy Reinforced

ACAR conductor is formed by wrapping strands of high purity aluminum (aluminum 1350) on high strength Aluminum-Magnesium-Silicon alloy (6201 aluminum alloy) core. ACAR has better electrical as well as mechanical properties than equivalent ACSR conductors. ACAR conductors may be used in overhead transmission as well as distribution lines.

bare-conductor-overhead-line

When selecting a conductor type, factors such as line length, voltage level, environmental conditions, and cost should be considered.Quick Quote

  • AAC: Lightweight, economical, used for short distances.
  • AAAC: Good strength, light weight, suitable for medium distance routes.
  • ACSR: Strongest, used for long distance and high voltage lines.
  • ACAR: Balanced Strength & Weight, Ideal for Long Spans with Moderate Tension.

Aluminum Overhead Line Popular sizes

Aluminum Overhead Line Products can be manufactured and supplied on non-recyclable wooden/steel reels or recyclable steel reels.Quick Quote

AAC size

Size - AWG or MCM Nominal Cross Sectional Area Nominal Weight kg/km
3/0 84.91mm2 234.4
397.5 202.1mm2 55.4
795 402.9mm2 1110.6
1750 885.8mm2 2445.1

AAAC size

Size - KCM Nominal Cross Sectional Area Nominal Weight kg/km
30.58 0.610mm2 503.49
312.8 6.238mm2 4989.52
740.8 19.863mm2 13834.57

ACSR size

Size - AWG - MCM Nominal Cross Sectional Area Nominal Weight kg/km
4 26.47mm2 92.3
336.4 198.4mm2 689
1272 489.1mm2 2134.1

Cables sizes are available as AWG in cmill, kcmill and MCM.Quick Quote

Characteristics of Overhead Line Aluminium Conductors

The property of Overhead Line Aluminium Conductors

Mechanical properties
Nominal diameter dmm 6101 6201
Tensile strength MPa Elongation % Tensile strength MPa Elongation %
2.00≤d<3.0 ≥250 ≥3.5 ≥290 ≥3.0
03.00≤d<3.5 ≥240 ≥3.5 ≥275 ≥3.0
03.50≤d<4.0 ≥240 ≥3.5 ≥265 ≥3.0
04.00≤d≤5.00 ≥230 ≥3.5 ≥255 ≥3.0
Resistivity
Type 6101 6201
Conductivity ≥58.5% IACS ≥57.0% IACS

Related Popular Recommended Products

Characteristics of Overhead Line Aluminium Conductors

Good tensile strength and creep resistance: medium-strength aluminum alloy wires usually have high tensile strength and creep resistance, which can withstand long-term stable working loads and prolong the service life of the wires.

Excellent resistance and voltage drop characteristics: intermediate strength aluminium alloy wires has low resistance and voltage drop, which can reduce energy loss and power loss, and improve the efficiency of power transmission.

Superior strength: compared with ordinary aluminum conductors, Intermediate strength aluminium alloy wires used on overhead stranded wires have higher specific strength and can withstand greater tension and loads. This makes it even better at transporting long distances and spanning large support structures.

Lightweight: compared with copper wires, medium-strength aluminum alloy wires are lighter in weight, which makes it more convenient for suspended installation or long-distance transmission. In addition, the lighter weight reduces installation and maintenance costs.

Strong adaptability: intermediate strength aluminium alloy wires is suitable for different types of overhead lines, including transmission lines, distribution lines and branch lines. It can be used in different application scenarios, such as urban, rural, industrial areas, etc.Quick Quote

Good thermal conductivity: the medium-strength aluminum alloy wire has high thermal conductivity, which can effectively dissipate heat. This is very important for the performance and safety of power transmission lines and power equipment.

Good electrical conductivity: the Intermediate strength aluminium alloy wires used on the overhead stranded wire has good electrical conductivity and can effectively transmit power. Although it has slightly lower electrical conductivity than copper, medium-strength aluminum alloy wire is still a cost-effective choice.

Good anti-wind vibration performance: medium-strength aluminum alloy wires usually have good anti-wind vibration performance when used on overhead stranded wires, which can reduce wire vibration and swing caused by wind blowing, and improve the stability and reliability of the line.

Items for purchasing Overhead Line Aluminium Conductors

The application of Intermediate strength aluminum alloy wire for overhead conductors

Due to its advantages in manufacturing, design, construction, transportation, etc., Intermediate strength aluminium alloy wires is widely used in the field of transmission conductors.

Power transmission: intermediate strength aluminum alloy wire for overhead conductor are widely used in power transmission lines, including high-voltage transmission lines, medium-voltage transmission lines and low-voltage distribution lines. It can withstand high tensions and loads and is able to transmit power efficiently.

Overhead lines: Overhead Line Aluminium Conductors, including transmission lines between urban roads, rural areas, industrial areas, and power facilities. It can be hung from utility poles or towers for power transmission and distribution.

The application of Intermediate strength aluminum alloy wire for overhead conductors

Aluminum vs. Copper in Overhead Power Cables

Copeer and aluminum are two common types of electricity conductors in electrical cables. Power transmission lines span for hundreds of meters between the towers, so overhead cables have to be cost-efficient. Copper wires can be used in overhead wires to a satisfactory outcome. However, aluminum power cables are two times lighter compared to their copper counterparts and six times cheaper while maintaining the same resistance rate.

These properties make aluminum the best material for high-voltage transmission lines on the market, as overhead power cable has to be light and flexible in addition to being durable. Aluminum is a malleable material that is less prompt to compression stress compared to copper. This is a clear benefit as overhead cables are subjected to such stress. Utility companies have used aluminum since the beginning of the 20th century.

Today, about 13 percent of the aluminum produced is utilized in the energy sector. Aluminum wires have the perfect strength to weight ratio and are cost-efficient because they are not labor-intensive and save construction time.

Chalco can provide you the most comprehensive inventory of aluminum products and can also supply you customized products. Precise quotation will be provided within 24 hours.

Get a quote
Do you have the aluminum you need?

Welcome to contact us

  • Contact us to get quotation information
  • Contact us for the details of the product
  • Contact us to get free samples
  • Product demand
  • Name
  • Phone number or WhatsApp
  • Email
  • content